Air Flow: 1000 SCFM
Nominal Absorbed Power: 5.21 KW
Air Connection: 2-1/2″ NPT
Length: 46.1 in
Width: 36.4 in
Height: 44.5 in
Connections: 6.5 in
Net Weight: 630 lbs
Volts/Phase: 460/3
Hz: 60
(1) Air flow rate: data refers to the following conditions; air FAD 68°F/14.5 psi (a), pressure 100 psi (g), air inlet temperature 100°F, ambient temperature 100°F, air pressure 100°F , according to CAGI (ADF100) standards. Pressure dew point from 33°F to 39°F.
(2) Total dryer absorbed power at rated operating conditions and at 115/1/60 or 460/3/60 power supply.
(3) Weights are net (without packing and for timed drain configuration).
* Available on request.
Maximum inlet temperature: 158°F (DEiT 0010 – 0325); 135°F (DEiT 0425-DEiT 1000). Maximum ambient temperature: 115°F.
Minimum ambient temperature: 41°F. Maximum air pressure: 232 psig.
For applications with higher ambient or inlet temperatures, or higher pressures, please contact our sales offices.
Refrigerant fluids: R134a (DEiT 0010-DEiT 0325); R410A (DEiT0425-1000). Protection class.
A model selection and energy savings calculating software is available for dryer selection in conditions differing from the above. The below correction factors should be used as a guide only.
air pressure | psi | 50 | 75 | 100 | 125 | 150 | 232 |
---|---|---|---|---|---|---|---|
correction factor | K1 | 0.77 | 0.90 | 1.00 | 1.07 | 1.12 | 1.23 |
pressure dew point | °F | 38 | 40 | 45 | 50 |
---|---|---|---|---|---|
correction factor | K2 | 1.00 | 1.05 | 1.21 | 1.36 |
air inlet temperature | °F | 90 | 100 | 110 | 120 | 130 | 149 | 158 |
---|---|---|---|---|---|---|---|---|
correction factor | K3 | 1.23 | 1.00 | 0.81 | 0.68 | 0.61 | 0.49 | 0.44 |
ambient temperature | °F | 90 | 100 | 110 | 115 |
---|---|---|---|---|---|
correction factor | K4 | 1.07 | 1.00 | 0.93 | 0.88 |